56K Softmodem
Command Reference
- 42
Table 3-73: +EFRAM Extended Syntax Commands
+ER=<value>—Error Control Reporting
Use this command to turn on or turn off the error control report. If the compression
report is enabled, the +ER:<type> intermediate result code reports the current
DCE-DCE error control type. It is issued after the determination of the error
control protocol and before the final result code (e.g., CONNECT). Specifically,
the +ER intermediate result code is issued after the modulation report (+MCR and
+MRR) and before the data compression report (+DR).
Result codes:
OK if <value> = 0, 1.
ERROR if <value> does not equal 0, 1.
Command Description
+EFRAM=<value 1>,<value 2> Sets the link-layer frame fields size.
+EFRAM? Displays the current maximum link-layer frame field size settings.
+EFRAM=? Displays the supported maximum frame sizes.